Based on your query, you are looking for a 75kW Variable Frequency Explosion-Proof Motor paired with a High Pressure Centrifugal Fan Blower.
This is a specific industrial combination used for demanding applications where explosive gases or dust are present (e.g., oil & gas, chemical plants, mining) and where high static pressure is required to move air through restrictive ductwork.
Here is a breakdown of the technical specifications, typical configurations, and key purchasing considerations for this unit.
Motor Specifications (The Driver)
- Power: 75 kW (approx. 100 HP).
- Type: Variable Frequency Drive (VFD) compatible. This usually means it is an Inverter Duty motor (marked as "VFD" or "Vector Duty").
- Note: The motor itself is not the VFD. You will need a separate Explosion-Proof VFD (Variable Frequency Drive) to control the speed.
- Explosion Proof Rating:
- ATEX: II 2G Ex d IIB T4 or T3 (for Gas).
- IECEx: Ex d IIB T4 Gb.
- UL/NEC: Class I, Division 1, Groups C & D; or Class I, Zone 1, Group IIB.
- RPM: Usually 2900-3000 RPM (2-pole) for high pressure. A 4-pole (1450-1500 RPM) motor is possible but will require a larger fan wheel to achieve the same pressure.
Fan Specifications (The Blower)
- Type: Centrifugal High Pressure (often "B-Type" or "Radial" / "Paddle Wheel" design).
- Configuration: Usually Direct Drive (motor shaft connected directly to the fan impeller) is preferred for VFD reliability, but Belt Drive is possible for non-critical speed changes.
- Typical Performance Range (approximate):
- Airflow: 10,000 m³/h to 30,000 m³/h (5,800 to 17,500 CFM).
- Static Pressure: 6,000 Pa to 15,000 Pa (24 to 60 inches w.g.), depending on the fan wheel design (backward inclined vs. radial).
Key Components & Configuration
- Impeller: For explosion-proof applications, the impeller must be non-sparking (made of aluminum, bronze, or stainless steel) or use a spark-resistant coating/mesh lining.
- Housing: Cast iron or heavy steel plate. A drain plug is mandatory for condensation removal in duct systems.
- Shaft Seal: Required to prevent gas leakage from the process into the motor room.
- Baseplate: Heavy-duty steel channel skid.
The Critical Interface: VFD + Motor
- Cable: You MUST use armored or shielded cable specifically rated for VFD drives and explosion-proof connections.
- Filter: You will likely need a dv/dt filter or a sine-wave filter at the motor terminals if the cable run between the VFD and motor is long (>50m / 150ft) to prevent motor winding burnout.
- VFD Location: The VFD itself is usually not located in the hazardous area. If it must be, you need a purged (Type Z or Type X) VFD enclosure.
Potential Applications (Where this unit is used)
- Boiler Induced Draft (ID) / Forced Draft (FD): In refineries or biomass plants in Zone 2 areas.
- Mine Ventilation: For main mine fans requiring high pressure.
- Chemical Reactor Off-Gas: Moving corrosive and explosive vapors.
- Flue Gas Desulfurization (FGD): In coal power plants.
- Pneumatic Conveying: Moving bulk powders in classified explosive zones (e.g., grain dust, coal dust).
Important Purchasing Checklist
Before contacting a supplier like Greenheck, New York Blower, Howden, Cincinnati Fan, or Chinese equivalents like Jiangsu Tongli, Zibo, or Shanghai Ventax, you need to provide these specifications:
- Fluid Being Moved: (e.g., Natural gas/Methane, Hydrogen, Wood Dust, Ammonia). This determines ATEX group (IIA, IIB, IIC).
- Temperature Class: T4 (max 135°C) or T3 (max 200°C). The motor running at 75kW can get hot; the fan must handle the thermal event.
- Flow Rate (m³/h or CFM):
- Static Pressure (Pa or inches w.g.): (Critical for "High Pressure" designation; must be > 12" w.g. / 3000 Pa).
- Ambient Temperature: (Standard -20°C to +40°C, or higher?).
- Altitude: (Affects motor cooling and air density).
- Mounting: (Indoor/Outdoor; Vertical/Horizontal).
Summary Table (Typical Unit)
| Specification | Value |
|---|---|
| Motor Power | 75 kW (100 HP) |
| Motor Speed | 2900 RPM (Direct Drive) |
| Motor Type | Inverter Duty, Explosion-Proof (Ex d) |
| Standards | ATEX, IECEx, or NEC (Class I Div 1) |
| VFD | Required (External, separate) |
| Fan Type | Radial Blade, High Pressure |
| Impeller Material | Aluminum / Stainless Steel (Non-Sparking) |
| Max Temp (Gas stream) |
T3 (200°C) / T4 (135°C) |
Final Warning
A 75kW fan is a high-energy rotating machine. In an explosion-proof context, startup and maintenance are critical.
- Never run a VFD at the motor's nameplate frequency (50/60Hz) without proper setup.
- Always ensure the fan housing is grounded.
- Inspection: The gap between the impeller and the inlet cone must be verified; a "rub" can create sparks and an explosion.
If you have specific manufacturer names, dimensions (e.g., Inlet/Outlet size), or certification requirements (ATEX Zone 1 vs Zone 2), please provide them for a more precise match.